Dual Test Gas Pulmonary Diffusing Capacity Measurement During Exercise in Humans Using the Single-Breath Method
Published on: February 2, 2024
Breath-by-breath fluctuations of pulmonary gas exchange and ventilation in COPD patients
Luis Puente-Maestu1, Ma Jesús Buendía Abad, Raul Godoy
1Hospital General Universitario Gregorio Marañón, Servicio de Neumología, c/ Doctor Ezquerdo 46, 28007 Madrid, Spain. lpuente@separ.es
Abstract:
The purpose of the study was to characterise statistically the inherent fluctuations in breath-by-breath measurements of pulmonary gas exchange (oxygen uptake and carbon dioxide output, V*O2 and V*CO2, respectively) and pulmonary ventilation (V*E) in patients with chronic obstructive pulmonary disease (COPD) and to compare them with those of healthy control subjects. Thirty subjects with COPD [mean (SD): 67 (6) years old; forced expiratory volume in 1 min, FEV1 1.25( 0.18) l; 42 (6)% predicted FEV1] and 12 healthy subjects [31 (3) years old; FEV1 3.62 (0.54) l; 99 (8)% predicted FEV1] performed exercise tests on a cycle ergometer at a constant work rate of moderate intensity. Steady-state exercise values for V*O2, V*CO2 and V*E were 905 (96) ml.min(-1), 847(90) ml.min(-1) and 23 (3) l.min(-1), respectively for the COPD patients and 1239(89) ml.min(-1), 1191(84) ml.min(-1)and 37(3) l.min(-1), respectively, for the healthy controls. The breath-by-breath fluctuations were well characterised by a Gaussian density-probability function with breath-to-breath autocorrelations that were not significantly different from 0, up to four subsequent breaths. Its magnitude varied among variables, but was independent of the signal amplitude for the same subject and variable. With ratios of amplitude of fluctuation:signal of around 10%, typical of the patients studied, the resolution of time constants and amplitude were congruent with 9 s and congruent with 100 ml.min(-1), respectively for V*O2 or V*CO2 with one repetition.
More Related Videos
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration can...
Pulmonary Cycle: Exhalation
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...