Related Experiment Video
Updated: Sep 28, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Workplace monitoring for volatile organic compounds using thermal desorption-gas chromatography-mass spectrometry
Ardith A Grote1, Eugene R Kennedy
1Chemical Exposure and Monitoring Branch, Division of Applied Research and Technology, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Cincinnati, OH 45226, USA.
Abstract:
The interest in the identification of volatile organic compounds in the workplace has been a major focus of many National Institute for Occupational Safety and Health (NIOSH) field studies. A primary technique for sampling and analysis of these compounds is summarized by NIOSH Manual of Analytical Methods (NMAM) 2549. This is a screening method that uses a multi-bed sorbent to trap a wide variety of compounds and compound classes. Thermal desorption techniques are used as a first attempt to characterize potential contaminants in a workplace and to determine what future sampling and analyses must be performed. Field examples are provided to show the versatility of thermal desorption methods and techniques. Due to their sensitivity, thermal desorption tube methods are sometimes required in order to measure the workplace concentrations of unusual compounds. In other situations, the exposures are too high or varied to make thermal desorption tubes practical. In these cases, the identification of contaminants with thermal desorption tubes leads to new method developments for the quantification of specific compounds using more conventional solid sorbent-solvent desorption based methods.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
05:22Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Volatilization