Is the real-ear to coupler difference independent of the measurement earphone?
Kevin J Munro1, Vanessa A Salisbury
1ISVR Hearing and Balance Centre, University of Southampton, UK. kevin.j.munro@man.ac.uk
Abstract:
Direct measurement of real-ear hearing aid performance can be obtained using a probe tube microphone system. Alternatively, it can be derived by adding the real-ear to coupler difference (RECD) to the electroacoustic performance of the hearing instrument measured in a 2-cc coupler. Inherent in this derivation is the assumption that the RECD measured with one transducer can be applied to a coupler measurement performed with a different transducer. For the RECD procedure to be valid, it should be independent of the measurement transducer. The Audioscan RM500 is an example of a commercially available real-ear measurement system that incorporates a clinical protocol for the measurement of the RECD. The RECD can be measured on the Audioscan RM500 using a standard EAR-Tone ER-3A insert earphone or the Audioscan's own RE770 insert earphone. The aim of this study was to compare the RECDs obtained with these two earphones. The Audioscan RM500 was used to measure the RECD from the right ears of 18 adult subjects ranging in age from 22 to 36 years (mean 25 years). Measurements were made with the EAR-Tone ER-3A and RE770 insert earphone and three earmould configurations: (1) the EARLINK foam ear-tip; (2) a hard acrylic shell earmould with the same length of acoustical tubing as the foam ear-tip (25 mm); and (3) the shell ear mould with the appropriate length of tubing for a behind-the-ear (BTE) hearing aid fitting (approximately 35-45 mm). The results show that the mean RECD was around 3 dB higher at 1.5 kHz with the foam ear-tip when measured with the RE770 earphone than when measured with the ER-3A earphone. The same magnitude of difference was obtained with the shell earmould and 25-mm tubing; however, this increased to 9 dB when the tubing was increased to around 40 mm for a BTE fitting. The difference in mean RECD with the two earphones was statistically significant on a repeated-measures ANOVA for every earmould configuration (p<0.001). The results of this study demonstrate that the RECD procedure that uses an HA2 coupler and earmould is not independent of the measurement earphone. This has important implications for clinical practice.
Related Concept Videos
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case, then the...
Anatomy of the Ear
Perception of Sound Waves
The pitch of a sound depends on the frequency and the pressure amplitude of the source. Two sounds of the same frequency...
Characteristics of Practical Op Amps
The ratio of differential gain to the common-mode gain is defined as the common-mode rejection ratio (CMRR). This ratio quantifies the ability of operational amplifiers (op-amps) to reject common-mode...
Interference: Path Lengths
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and hence a...