Related Experiment Video
Updated: Sep 28, 2026

Multi-Modal Home Sleep Monitoring in Older Adults
Published on: January 26, 2019
[Screening measurements for sleep apnea: is a single measurement enough?]
Abstract:
In patients with sleep apnea syndrome a high night by night variability of the respiratory breathing disturbance was reported in some studies. In the following study the variability of the apnoe-/hypopnoeindex (AHI) was prospectively determined with an ambulant monitoring system. Outpatients were instructed to perform three measurement at home independently. The influence of the variability was determined with respect to a first night effect (FNE), body position, severity of SAS, age and sex of the patients. 19 patients (12 men and 7 women, mean age 51.6 +/- 12.4 years) were investigated. The measurements were done with the ambulatory device Jaeger pro (ViaSys Comp., Wuerzburg). No statistically significant differences of the AHI and the cardiorespiratory parameters between the 3 nights were found (AHI 9.8 +/- 11.7/h, 10.1 +/- 9.6/h vs. 8.5 +/- 9.0/h). However the individual AHI difference was 5,6 +/- 5,0/h. In 15 % of the patients the AHI varied even by more than 10 per h. The variability of the AHI was associated with the severity. No FNE, dependency of body position, sex or age was found. Due to the individual variability of the AHI severity in patients with sleep apnoe syndrome, the severity is underestimated in a considerable number of patients. Repetitive measurements improve the diagnostic power.
More Related Videos
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:

