Heterogeneity of contrast effect during intermittent second harmonic myocardial contrast echocardiography in healthy
Taniyel Ay1, Anne-Marie D'Hondt, Agnès Pasquet
1Division of Cardiology, Université Catholique de Louvain, School of Medicine, Brussels, Belgium.
Insights
Parametric imaging reduces contrast heterogeneity in myocardial perfusion studies. This technique improves image quality by enhancing homogeneity compared to conventional methods, aiding in the detection of coronary disease.
Area of Science:
- Cardiovascular Imaging
- Medical Ultrasound
- Image Processing
Background:
- Intermittent harmonic imaging with contrast is vital for detecting perfusion defects in coronary disease.
- Image homogeneity and visualization of distal segments are crucial for accurate assessment.
- Current methods may present challenges in achieving optimal image quality.
Purpose of the Study:
- To evaluate postprocessing algorithms for improved image homogeneity in contrast-enhanced ultrasound.
- To compare parametric display and background subtraction with color coding against conventional imaging.
- To assess the impact on myocardial opacification heterogeneity.
Main Methods:
- Contrast echocardiography with perfluorocarbon-enhanced sonicated dextrose albumin in 20 healthy participants.
- Acquisition of end-systolic images at varying pulsing intervals (300-ms).
- Image analysis included alignment, averaging, background subtraction, color coding, and generation of parametric images (beta and A) to quantify heterogeneity.
Main Results:
- Myocardial opacification heterogeneity exceeded 20% across all tested methods.
- Parametric images of beta and A showed significantly lower heterogeneity (24 ± 14% and 24 ± 8%) compared to gray-scale second harmonic (39 ± 13%) and color-coded (47 ± 16%) images (P < .05).
- Basal- and apical-lateral segments contributed most to heterogeneity, reduced with parametric imaging.
Conclusions:
- Myocardial opacification is frequently heterogeneous, even in healthy individuals.
- Parametric imaging offers a reduction in contrast effect heterogeneity, improving overall image quality.
- This advancement aids in more reliable detection of perfusion defects in cardiac patients.
Abstract:
Intermittent harmonic imaging with contrast is increasingly used to detect perfusion defects in patients with coronary disease. To achieve this, image homogeneity and the ability to visualize segments on the lateral and distal portions of the imaging field are important. The objective of this study was to evaluate whether the use of specific postprocessing algorithms, such as background subtraction with color coding and parametric display, allows for improved image homogeneity compared with conventional intermittent second harmonic imaging. For this purpose, 20 participants who were free of cardiac abnormalities and in whom myocardial perfusion should by definition be homogeneously distributed, underwent contrast echocardiography during the constant intravenous infusion of 1.0 +/- 0.3 mL/min of perfluorocarbon-enhanced sonicated dextrose albumin. End-systolic ECG-triggered images were obtained from the apical 4-chamber view at pulsing intervals of 300-ms 1, 3, 5, and 8 cardiac cycles. For analysis, each set of images was aligned, averaged, background subtracted, and color coded. Pulsing intervals versus videointensity plots were then generated for each pixel in the images and fitted to an exponential function to produce parametric images of beta (an index of microbubble velocity) and A (a measure of myocardial blood volume). The heterogeneity of the contrast effect was evaluated by computing the coefficients of variation in each image. Contrast heterogeneity was >20% with all 4 methods. However, it was greater in gray-scale second harmonic (39 +/- 13%) and color-coded (47 +/- 16%) images than in parametric images of beta and A (24 +/- 14 and 24 +/- 8%, respectively; both P <.05 vs gray-scale second harmonic and color-coded images). With all 4 methods, basal- and apical-lateral segments contributed most to image heterogeneity, albeit significantly less so with parametric imaging. In conclusion, our data indicate that myocardial opacification is frequently heterogeneous in healthy participants, particularly when using gray-scale second harmonic and background-subtracted with color-coding imaging. Parametric imaging allows reduction, albeit incomplete, of the heterogeneity of the contrast effect and therefore improves image quality.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...

