Related Experiment Video
Updated: Aug 13, 2026

A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Simultaneous identification/determination system for phentolamine and sildenafil as adulterants in soft drinks
Eiichi Mikami1, Tsutomu Ohno, Hiroshi Matsumoto
1Aichi Prefectural Institute of Public Health, 7-6 Nagare, Tsuji-machi, Kita-ku, Nagoya 462-8576, Japan. eiichi_mikami@mail.pref.aichi.jp
Abstract:
An easily available, simultaneous identification/determination procedure for phentolamine (PHE) and sildenafil (SIL) in adulterated dietary supplements was established by using a combination of three different analytical methods; thin-layer chromatography (TLC), liquid chromatography-mass spectrometry (LC/MS) and a high-performance liquid chromatography (HPLC)/photo-diode-array. The sample solution for TLC was applied to silica gel 60 F(254) plates with chloroform/ammonia solution (28)/methanol (70:5:3, lower layer) and chloroform/diethylamine/methanol (15:3:2) as the developing solvent. Spots were located under UV radiation at 254 nm. Mass spectra of PHE and SIL by LC/MS were investigated with electrospray ionization (ESI) interface, under both positive and negative ion mode. The HPLC analysis was performed on a column of Wakosil 5C18 (4.6 mm x 150 mm, 5 microm) with water/methanol/acetonitrile/triethylamine (580:250:170:1) adjusted with phosphoric acid to pH 3.0 as the mobile phase, and the effluent was monitored with a photo-diode-array detector. Quantitative HPLC analysis of PHE and SIL were detected at 280 nm. When this procedure was applied to commercial soft drinks, PHE and SIL were identified and determined at a concentration of 17 mg PHE and 44 mg SIL per bottle, respectively. The procedure described here is available for the screening of PHE and SIL in adulterated supplements.
Related Concept Videos
Pharmacovigilance
This process, termed pharmacovigilance, aims to detect, evaluate, and minimize harmful effects related to medication use. The data collection for pharmacovigilance depends on spontaneous reporting systems, where healthcare professionals or patients voluntarily report suspected ADRs.
In some cases, there...
Adrenergic Agonists: Mixed-Action Agents
Ephedrine and pseudoephedrine lack a catecholamine group, making them less susceptible to degradation by metabolic enzymes. They have increased oral bioavailability and lipophilicity, resulting in a longer duration of action. Their response is reduced by...

