Quantitative Autonomic Testing
Published on: July 19, 2011
Continuous recording of dicrotic and pulse pressures during head-up tilting test: the vasodepressive profile.
Salvatore M Romano1, Chiara Lazzeri, Marco Chiostri
1Department of Critical Care, University of Florence, School of Medicine, Florence, Italy.
Background:
The aim of this study was to assess whether a non-invasive automatic evaluation of the pulse wave characteristics could provide clinical clues when monitoring the hemodynamic adjustments to head-up tilting.
Methods:
A continuous assessment of the peripheral pulse wave characteristics (systolic, diastolic, dicrotic and pulse pressures) in 8 control subjects with a negative response to head-up tilting (60 degrees for 45 min) compared to 13 syncopal patients with a vasodepressive one was performed.
Results:
Controls exhibited, when up-tilted, an increase in blood pressure as well as in the dicrotic and pulse pressures and no changes in heart rate. On the contrary, syncopal patients showed a progressive increase in heart rate associated with a progressive decrease in dicrotic pressure and a trend towards lower values of pulse pressure, but no changes in systolic pressure. Thereafter and until the pre-syncopal symptoms supervened, the systolic, diastolic and dicrotic pressures progressively declined. A decrease in dicrotic pressure mainly characterized the early vasodepressive response while its increase identified the negative one.
Conclusions:
Our data, even though preliminary, strongly suggest that automatic hemodynamic evaluation is to be used in the clinical setting as a monitor of the sudden changes in blood pressure induced by head-up tilting. Furthermore, the dicrotic and pulse pressures, even those measured during the early phases of the test, should be considered as non-invasive parameters characterizing the vasodepressive response to head-up tilting.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure