Related Experiment Video
Updated: Aug 17, 2026

The Fabrication and Operation of a Continuous Flow, Micro-Electroporation System with Permeabilization Detection
Published on: January 7, 2022
Mechanism for membrane electroporation irreversibility under high-intensity, ultrashort electrical pulse conditions
1Department of Electrical and Computer Engineering, Old Dominion University, Norfolk, Virginia 23529-0246, USA.
Abstract:
An improved electroporation model is used to address membrane irreversibility under ultrashort electric pulse conditions. It is shown that membranes can survive a strong electric pulse and recover provided the pore distribution has a relatively large spread. If, however, the population consists predominantly of larger radii pores, then irreversibility can result. Physically, such a distribution could arise if pores at adjacent sites coalesce. The requirement of close proximity among the pore sites is more easily satisfied in smaller organelles than in outer cell membranes. Model predictions are in keeping with recent observations of cell damage to intracellular organelles (e.g., mitochondria), without irreversible shock at the outer membranes, by a nanosecond, high-intensity electric pulse. This mechanism also explains the greater damage from multiple electric shocks.