Using nitrile-derivatized amino acids as infrared probes of local environment
Zelleka Getahun1, Cheng-Yen Huang, Ting Wang
1Department of Chemistry, University of Pennsylvania, Philadelphia 19104, USA.
Abstract:
It is well-known that the C=N stretching vibration in acetonitrile is sensitive to solvent. Therefore, we proposed in this contribution to use this vibrational mode to report local environment of a particular amino acid in proteins or local environmental changes upon binding or folding. We have studied the solvent-induced frequency shift of two nitrile-derivatized amino acids, which are, AlaCN and PheCN, in H(2)O and tetrahydrofuran (THF), respectively. Here, THF was used to approximate a protein's hydrophobic interior because of its low dielectric constant. As expected, the C=N stretching vibrations of both AlaCN and PheCN shift as much as approximately 10 cm(-1) toward higher frequency when THF was replaced with H2O, indicative of the sensitivity of this vibration to solvation. To further test the utility of nitrile-derivatized amino acids as probes of the environment within a peptide, we have studied the binding between calmodulin (CaM) and a peptide from the CaM binding domain of skeletal muscle myosin light chain kinase (MLCK(579-595)), which contains a single PheCN. MLCK(579-595) binds to CaM in a helical conformation. When the PheCN was substituted on the polar side of the helix, which was partially exposed to water, the C=N stretching vibration is similar to that of PheCN in water. In constrast, when PheCN is introduced at a site that becomes buried in the interior of the protein, the C=N stretch is similar to that of PheCN in THF. Together, these results suggest that the C=N stretching vibration of nitrile-derivatized amino acids can indeed be used as local internal environmental markers, especially for protein conformational studies.
More Related Videos
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Emission Spectroscopy: Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Lab