Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Breathing pattern and workload during automatic tube compensation, pressure support and T-piece trials in weaning
1University of Aachen Medical School, Department of Anesthesiology, Aachen, Germany. Ralf.Kuhlen@post.rwth-aachen.de
Background And Objective:
Automatic tube compensation has been designed as a new ventilatory mode to compensate for the non-linear resistance of the endotracheal tube. The study investigated the effects of automatic tube compensation compared with breathing through a T-piece or pressure support during a trial of spontaneous breathing used for weaning patients from mechanical ventilation of the lungs.
Methods:
Twelve patients were studied who were ready for weaning after prolonged mechanical ventilation (10.2 +/- 8.4 days) due to acute respiratory failure. Patients with chronic obstructive pulmonary disease were excluded. Thirty minutes of automatic tube compensation were compared with 30 min periods of 7 cmH2O pressure support and T-piece breathing. Breathing patterns and workload indices were measured at the end of each study period.
Results:
During T-piece breathing, the peak inspiratory flow rate (0.65 +/- 0.20 L s(-1)) and minute ventilation (8.9 +/- 2.7L min(-1)) were lower than during either pressure support (peak inspiratory flow rate 0.81 +/- 0.25 L s(-1) minute ventilation 10.2 +/- 2.3 L min(-1), respectively) or automatic tube compensation (peak inspiratory flow rate 0.75 +/- 0.26L s(-1); minute ventilation 10.8 +/- 2.7 L min(-1)). The pressure-time product as well as patients' work of breathing were comparable during automatic tube compensation (pressure-time product 214.5 +/- 104.6 cmH2O s(-1) min(-1), patient work of breathing 1.1 +/- 0.4 J L(-1)) and T-piece breathing (pressure-time product 208.3 +/- 121.6 cmH2O s(-1) min(-1), patient work of breathing 1.1 +/- 0.4 J L(-1)), whereas pressure support resulted in a significant decrease in workload indices (pressure-time product 121.2 +/- 64.1 cmH2O s(-1) min(-1), patient work of breathing 0.7 +/- 0.4 J L(-1)).
Conclusions:
In weaning from mechanical lung ventilation, patients' work of breathing during spontaneous breathing trials is clearly reduced by the application of pressure support 7 cmH2O, whereas the workload during automatic tube compensation corresponded closely to the values during trials of breathing through a T-piece.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Cardiopulmonary Resuscitation II: ACLS Airway Management