Related Experiment Video
Updated: Feb 13, 2026

Continuous-wave Thulium Laser for Heating Cultured Cells to Investigate Cellular Thermal Effects
Published on: June 30, 2017
Reduction in lateral thermal damage using heat-conducting templates: a comparison of continuous wave and pulsed CO2
Nicole Spector1, Jared Spector, Darrel L Ellis
1Department of Medicine, Division of Dermatology, Vanderbilt University Medical Center, Nashville, Tennessee 37232-5227, USA.
Background And Objectives:
The advantages of the continuous wave (c.w.) CO(2) laser are offset by the delay in laser wound healing secondary to thermal damage. We have developed novel heat-conducting templates to reduce laser thermal damage. Because shortened pulse durations also decrease thermal damage, we tested the effectiveness of heat-conducting templates with a c.w. CO(2) clinical laser and a short-pulsed CO(2) laser to determine the best method and mechanism to minimize thermal damage.
Study Design/Materials And Methods:
Comparison of 0.2-second shuttered c.w. and 5-microsecond pulsed CO(2) lasers were made by doing incisions on 150 tissue samples from reduction mammoplasties and abdominoplasties. Copper, aluminum, glass, and Plexiglass heat-conducting templates were tested against no template (air) with both lasers. Histological samples were evaluated using computerized morphometrics analysis.
Results:
Statistically significant reductions in lateral thermal damage were seen with the copper (50%) and aluminum (39%) templates used with the c.w. CO(2) laser. Only the copper template (39%) significantly reduced thermal damage when used with the pulsed CO(2) laser. Less thermal damage was seen using the pulsed CO(2) laser compared to the c.w. CO(2) laser with each template.
Conclusions:
Heat-conducting templates significantly reduced the amount of lateral thermal damage when used with the c.w. CO(2) laser (copper and aluminum) and short-pulsed CO(2) laser (copper). The c.w. CO(2) laser with the copper template compared favorably to the short-pulsed CO(2) laser without a template. Therefore, both heat conductive templates and short-pulse structure provide successful methods for reducing lateral thermal damage, and a combination of the two appears to provide optimal results.
More Related Videos
Related Concept Videos
Quantifying Heat
Heating and Cooling Curves
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...
DNA as a Genetic Template
DNA as a Genetic Template
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...

