Using a passive multilayer sampler for measuring detailed profiles of gas-phase VOCs in the unsaturated zone
Yael Laor1, Daniel Ronen, Ellen R Graber
1Institute of Soil, Water and Environmental Sciences, The Volcani Center, Agricultural Research Organization, P.O.B 6, Bet-Dagan, Israel 50250. laor@volcani.agri.gov.il
Abstract:
The purpose of this study was to test in the laboratory the performance of a passive multilayer sampler (MLS) for obtaining detailed profiles of gas-phase volatile organic compounds (VOCs) in unsaturated sediments. The MLS is essentially a chain of isolated, cylindrical stainless steel dialysis cells filled with distilled water and closed with membranes at both ends. The sampling principle is based on passive equilibration of the unsaturated zone gas phase with water in the cells. Using trichloroethene (TCE) as a model VOC, and after testing the required equilibration time in the laboratory (about 50 h), results of a large container (210 L) experiment show that TCE concentrations obtained by the MLS deployed inside a well screen corresponded very well to the profile obtained by dialysis cells buried in the sediment. A field profile taken at the saturated-unsaturated interface region of a VOC-contaminated area using the MLS shows steep TCE concentration gradients (1119 microg TCE/L-air/cm) in the gas phase of the unsaturated zone just above the water table.
More Related Videos
10:29Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
Related Concept Videos
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Volatilization
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...