Local drug delivery via a coronary stent with programmable release pharmacokinetics
Ariel Finkelstein1, Dougal McClean, Saibal Kar
1Division of Cardiology, Cedars-Sinai Medical Center and Department of Pathology at UCLA School of Medicine, 90048, USA.
Background:
Fixed drug release kinetics and vessel wall partitioning may limit the effectiveness of drug-eluting stents. We report preliminary experience using a new coronary stent with programmable pharmacokinetics.
Methods And Results:
A newly designed metallic stent contains honeycombed strut elements with inlaid stacked layers of drug and polymer. In vitro studies evaluated recipes for loading paclitaxel to establish the parameters for controlling drug release. Manipulation of the layers of biodegradable polymer and drug allowed varying of the initial 24-hour burst release of paclitaxel from 69% to 8.6% (P<0.0001). Late release of drug could be adjusted dependently or independently of early burst release. A biphasic release profile was created by the addition of blank layers of polymer within the stack. In the 30-day porcine coronary model (n=17 pigs), there was a 70% reduction in late loss (0.3+/-0.5 versus 1.0+/-0.5 mm, P=0.04), a 28% increase in luminal volume (132+/-12 versus 103+/-21 mm(3), P=0.02), and a 50% decrease in histological neointimal area (2.0+/-0.5 versus 4.0+/-1.6 mm(2); P<0.001) compared with bare metal controls. Temporal and regional variations in vascular healing were seen histologically.
Conclusions:
Layered polymer/drug inlay stent technology permits flexible and controllable pharmacokinetic profiles. Programmable, complex chemotherapy using this approach may be feasible for the treatment of cardiovascular disease.
More Related Videos
10:28An Injectable and Drug-loaded Supramolecular Hydrogel for Local Catheter Injection into the Pig Heart
Published on: June 7, 2015
06:39Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
Published on: February 19, 2020
Related Concept Videos
Modified-Release Drug Delivery Systems: Rate-Programmed II
Modified-Release Drug Delivery Systems: Classification
Modified-Release Drug Delivery Systems: Rate-Programmed I
Modified-Release Drug Delivery Systems: Site-Targeted
Oral Drug Delivery Systems: Continuous-Release Systems
Oral Drug Delivery Systems: Delayed-Release Systems