Related Experiment Video
Updated: Aug 17, 2026

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
The effects of filling techniques and a low-viscosity composite liner on bond strength to class II cavities
André Figueiredo Reis1, Marcelo Giannini, Gláucia Maria Bovi Ambrosano
1Department of Restorative Dentistry/Operative Dentistry, Piracicaba School of Dentistry, UNICAMP. 901, 13414-900, Piracicaba, SP, Brazil.
Objective:
The aim of this study was to test the hypothesis that the effects of filling technique, cavity configuration and use of a low-viscosity composite liner influence resin bond strength to the dentin of class II cavities gingival floor; and analyze the failure modes of fractured specimens.
Methods:
Standardized class II cavities were prepared in the proximal surfaces of freshly extracted third molars, which were randomly assigned to 10 experimental groups. All prepared surfaces were acid-etched, bonded with Single Bond adhesive system and restored with TPH composite, according to each technique: G1 and G2-horizontal layering, G3 and G4-faciolingual layering, G5 and G6-oblique layering, G7 and G8-bulk filling, G9 and G10-control (flat dentin surfaces). Groups were tested, with or without a low-viscosity composite liner (Tetric Flow Chroma). After storage in water for 24h, teeth were vertically serially sectioned to yield a series of 0.8mm thick slabs. Each slab was trimmed into an hourglass shape of approximately 0.8mm(2) area at the gingival resin-dentin interface. Specimens were tested in tension at 0.5mm/min until failure. Fractured specimens were analyzed in an SEM to determine the failure modes.
Results:
No significant difference was found between groups restored with and without a low-viscosity composite liner (p>0.05). Among filling techniques, the bulk filling groups presented the lowest bond strength values (p<0.05), while incremental filling groups did not differ from control (flat dentin surfaces). Failure modes varied significantly among groups restored with and without the low-viscosity composite liner.
Significance:
Bond strengths were not improved when a low-viscosity composite liner was applied, but it remarkably influenced the failure modes. Incremental techniques improved bond strength.
More Related Videos
05:30Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Masonry Cavity Walls
Maintaining a clean cavity during construction is...
Bonding and Strength of Aggregate