Related Experiment Video
Updated: Jul 9, 2026

In Vivo Morphometric Analysis of Human Cranial Nerves Using Magnetic Resonance Imaging in Menière's Disease Ears and Normal Hearing Ears
Published on: February 21, 2018
Furosemide loading vestibular evoked myogenic potential for unilateral Ménière's disease
Toru Seo1, Michiko Node, Akiko Yukimasa
1Department of Otolaryngology, Hyogo College of Medicine, Nishiniomiya, Japan. tseo@hyo-med.ac.jp
Objective:
To investigate whether endolymphatic hydrops in Ménière's Disease could be diagnosed by comparing vestibular evoked myogenic potential (VEMP) before and after furosemide administration (F-VEMP).
Study Design:
Retrospective study.
Setting:
University hospital.
Intervention:
Furosemide administration.
Patients:
Twenty-five affected ears of patients with unilateral Ménière's Disease were studied. The patients had received confirmed diagnoses Ménière's Disease; thus, the presence of endolymphatic hydrops was suggested. For the control, 22 ears of 11 normal healthy volunteers who had never had vertigo or hearing disturbance were used.
Main Outcome Measure:
The amplitude of the p13-n23 biphasic wave before and after furosemide administration.
Results:
The amplitude of the p13-n23 biphasic wave was significantly enlarged in 7 of 18 cases in which it could be detected before diuretic loading. The biphasic waves appeared after diuretic loading in 3 of 7 cases in which it could not be recorded before loading. Thus, the positive ratio of F-VEMP for unilateral Ménière's Disease was considered to be 40% (10 of 25). The ratio was similar to that of the conventional examinations for endolymphatic hydrops such as the glycerol test, furosemide test, and electrocochleogram.
Conclusion:
The F-VEMP test may be useful in the diagnosis of endolymphatic hydrops.