Improved liquid chromatography/mass spectrometric analysis of low molecular weight carboxylic acids by ion exclusion
Keiji Gamoh1, Hiroki Saitoh, Hiroo Wada
1Faculty of Education, Kochi University, 5-1 Akebono-cho-2, Kochi 780-8520, Japan. kgamoh@cc.kochi-u.ac.jp
Abstract:
An improved, simple and sensitive analytical method for low molecular weight organic acids has been developed. A mixture of acetic, propionic, butyric, glycolic, lactic, 2-hydroxybutyric, malonic, succinic, glutaric, tartaric and citric acids was separated on a semi-rigid styrene-divinylbenzene copolymer-based H-type cation-exchange resin (ULTRON PS-80H) based on an ion exclusion chromatographic (IEC) mechanism, with detection using electrospray ionization mass spectrometry (ESI-MS). Formic or acetic acid was used as a mobile phase to separate the carboxylic acids within 15 min. For liquid chromatography/mass spectrometry (LC/MS), the ESI interface was used in both positive and negative ionization mode. ESI produced reasonable signals from positive ions, [M+NH(4)](+), of acetic, propionic and butyric acids and from negative ions, [M-H](-), of glycolic, lactic, 2-hydroxybutyric, malonic, succinic, glutaric, tartaric and citric acids. The effects of ionization parameters, source temperature, capillary voltage and cone voltage, on sensitivity and linearity were examined. Linear plots of peak area versus concentration were obtained over the range 0.1-20 ppm for MS detection. The detection limits of the target carboxylic acids calculated at signal-to-noise (S/N) ratio of 3 ranged from 9 to 59 ppb. The reproducibility of retention times and peak areas were 0.55-1.25 and 0.85-2.45%, respectively.
More Related Videos
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
10:41Ion Exchange Chromatography (IEX) Coupled to Multi-angle Light Scattering (MALS) for Protein Separation and Characterization
Published on: April 5, 2019
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Ion-Exchange Chromatography
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Mass Spectrometry: Carboxylic Acid, Ester, and Amide Fragmentation
For example, the fragmentation of...