Related Experiment Video
Updated: Aug 11, 2026

Application of Atomic Force Microscopy to Detect Early Osteoarthritis
Published on: May 24, 2020
Digital tomosynthesis of hand joints for arthritis assessment
J Duryea1, J T Dobbins, J A Lynch
1Osteoporosis and Arthritis Research Group, Department of Radiology, University of California, San Francisco, San Francisco, California 94143, USA. jduryea@bwh.harvard.edu
Abstract:
The two principal forms of hand arthritis, rheumatoid arthritis (RA) and osteoarthritis (OA) have large clinical and economic costs. Radiography has been shown to be a useful tool to assess the condition of the disease. A hand radiograph, however, is a two-dimensional projection of a three-dimensional object. In this report we present the results of a study that applied digital tomosynthesis to hand radiography in order to extract three-dimensional outcome measures that should be more sensitive to arthritis progression. The study was performed using simulated projection radiographs created using micro computed tomography (microCT) and a set of five dry-bone hand skeletons. These simulated projection images were then reconstructed into tomographic slices using the matrix inversion tomosynthesis (MITS) algorithm. The accuracy of the tomosynthesis reconstruction was evaluated by comparing the reconstructed images to a gold standard created using the microCT data. A parameter from image registration science, normalized mutual information, provided a quantifiable figure of merit. This study examined the effects of source displacement, number of reconstructed planes, number of acquisitions, noise added to the gray scale images, and errors in the location of a fiducial marker. We also optimized the reconstruction as a function of two variables k and alpha, that controlled the mixing of MITS with conventional shift-and-add tomosynthesis. A study using hand delineated joint margins demonstrated that MITS images provided a better measurement of average joint space width. We found good agreement between the MITS slices and the true planes. Both joint margins and trabecular structure were visible and the reconstructed slices showed additional structures not visible with the standard projection image. Using hand-delineated joint margins we compared the average joint space width of the gold standard slices to the MITS and projection images. A root-mean square deviation (RMSD), calculated for this comparison, gave RMSDproj = 0.18 mm and RMSDMITS = 0.14 mm for the projection and MITS images, respectively. We have demonstrated the potential of digital tomosynthesis for imaging of the hand to assess arthritic changes. We have also developed a methodology that can be used to optimize the technique and have studied the issues that will control the feasibility of clinical implementation.
Related Concept Videos
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies II: Ultrasonography

