Related Experiment Video
Updated: Sep 26, 2026

Determination of Cardiac Output in a Porcine Model for Ex Vivo Pulmonary Perfusion
Published on: June 28, 2024
Comparison of closed circuit and Fick-derived oxygen consumption in patients undergoing simultaneous aortocaval
J Hofland1, R Tenbrinck, C H J van Eijck
1Department of Anaesthesiology, Erasmus MC University Medical Centre Rotterdam, Rotterdam, The Netherlands. jan.hofland@tiscali.nl
Abstract:
Agreement between continuously measured oxygen consumption during quantitative closed system anaesthesia and intermittently Fick-derived calculated oxygen consumption was assessed in 11 patients undergoing simultaneous occlusion of the aorta and inferior vena cava for hypoxic treatment of pancreatic cancer. All patients were mechanically ventilated using a quantitative closed system anaesthesia machine (PhysioFlex) and had pulmonary and radial artery catheters inserted. During the varying haemodynamic conditions that accompany this procedure, 73 paired measurements were obtained. A significant correlation between Fick-derived and closed system-derived oxygen consumption was found (r = 0.78, p = 0.006). Linear regression showed that Fick-derived measure = [(1.19 x closed system derived measure) - 72], with the overall closed circuit-derived values being higher. However, the level of agreement between the two techniques was poor. Bland-Altman analysis found that the bias was 36 ml.min(-1), precision 39 ml.min(-1), difference between 95% limits of agreement 153 ml.min(-1). Therefore, we conclude that the two measurement techniques are not interchangeable in a clinical setting.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
12:37Surgical Placement of Catheters for Long-term Cardiovascular Exercise Testing in Swine
Published on: February 9, 2016
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiopulmonary Resuscitation II: ACLS Airway Management