Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Balance testing and Doppler monitoring during hyperbaric exposure
Stein H G Nordahl1, Torbjørn Aasen, Jan Risberg
1Department of Otolaryngology/Head and Neck Surgery, Haukeland University Hospital, Bergen, Norway. mail@fms.as
Background:
The effects on the postural system of saturation diving to shallow and medium depths have not previously been adequately tested. The purpose of this study was to investigate whether postural function is affected by a moderate hyperbaric exposure, and whether any deterioration is correlated with the presence of intravascular bubbles.
Hypothesis:
Postural control and the vestibulo-ocular reflex are not affected during heliox saturation diving to 5 meters of seawater (msw). At greater depths, an effect may occur.
Methods:
Postural control was tested with the subjects standing on a static balance platform before, during, and after onshore experimental saturation chamber dives to 5 msw heliox, 20 msw air, and to 100 msw heliox. Standard caloric testing with electronystagmography was performed before and after the heliox dives. Cardiac ultrasound and Doppler monitoring were used to detect possible venous gas emboli (VGE) during decompression in the heliox dives.
Results:
During the heliox exposure to 5 msw, no significant change in body sway was found. However, a significant change in body sway was found during an air dive to 20 msw and during the 100 msw heliox exposure. Caloric responses were unchanged immediately post-dive. After decompression from 5 msw, VGE were detected in two divers. During the 100 msw exposure, one case of VGE was observed.
Conclusions:
Exposure to hyperbaric heliox conditions corresponding to 5 msw, did not influence postural control significantly, while exposure to 100 msw heliox, and air diving to 20 msw, did. Although VGE were detected in the heliox dives, we could not find any correlation between this observation and postural instability.
More Related Videos
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure