Related Experiment Video
Updated: Sep 26, 2026

A Reversible, Non-invasive Method for Airway Resistance Measurements and Bronchoalveolar Lavage Fluid Sampling in Mice
Published on: April 13, 2010
Tracking variations in airway caliber by using total respiratory vs. airway resistance in healthy and asthmatic
1Department of Biomedical Engineering, 44 Cummington St, Boston, MA 02215, USA.
Abstract:
An index of airway caliber can be tracked in near-real time by measuring airway resistance (Raw) as indicated by lung resistance at 8 Hz. These measurements require the placing of an esophageal balloon. The objective of this study was to establish whether total respiratory system resistance (Rrs) could be used rather than Raw to track airway caliber, thereby not requiring an esophageal balloon. Rrs includes the resistance of the chest wall (Rcw). We used a recursive least squares approach to track Raw and Rrs at 8 Hz in seven healthy and seven asthmatic subjects during tidal breathing and a deep inspiration (DI). In both subject groups, Rrs was significantly higher than Raw during tidal breathing at baseline and postchallenge. However, at total lung capacity, Raw and Rrs became equivalent. Measured with this approach, Rcw appears volume dependent, having a magnitude of 0.5-1.0 cmH2O. l-1. s during tidal breathing and decreasing to zero at total lung capacity. When resistances are converted to an effective diameter, Rrs data overestimate the increase in diameter during a DI. Simulation studies suggest that the decrease in apparent Rcw during a DI is a consequence of airway opening flow underestimating chest wall flow at increased lung volume. We conclude that the volume dependence of Rcw can bias the presumed net change in airway caliber during tidal breathing and a DI but would not distort assessment of maximum airway dilation.
More Related Videos
Related Concept Videos
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Physical Assessment of the Respiratory Tract I: Health History
Subjective Data
Subjective data provides vital information about the patient's health history and symptoms. This data is typically collected through interviews in which patients describe their experiences, symptoms, and concerns.
Health history and key...
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration can...