Related Experiment Videos
Refractive outcome of Nidek OPD-scan customized ablations
Kozo Nakano1, Waldir Portellinha, Marivaldo Oliveira
1Excimer Laser Hospital Santa Cruz, São Paulo, Brazil. kozonakano@uol.com.br
Purpose:
Custom ablation is an improved refractive laser treatment that aims to optimize the optical system of the eye. We report preliminary results of laser in situ keratomileusis (LASIK) using customized ablation and the Nidek OPD-Scan.
Methods:
We report a prospective, non-comparative interventional case series. After OPD-Scan analysis, patients underwent LASIK. Eighty-four eyes were included: 44 eyes were treated with Flex Scan, 22 eyes with customized ablation based on Nidek OPD-Scan analysis, and 18 eyes were treated with conventional (scanning slit) ablation.
Results:
Visual outcome did not differ among groups. No patient experienced a significant decrease (more than 1 Snellen line) in best spectacle-corrected visual acuity.
Conclusions: