Imaging electrocardiographic dispersion of depolarization and repolarization during ischemia: simultaneous body
Martyn P Nash1, Chris P Bradley, David J Paterson
1University Laboratory of Physiology, University of Oxford, Oxford, UK. martyn.nash@auckland.ac.nz
Background:
Myocardial ischemia creates abnormal electrophysiological substrates that result in life-threatening ventricular arrhythmias. Identifying patients at risk of such abnormalities by use of body surface electrical measures is controversial. We investigated the sensitivity of torso measures, recorded simultaneously with epicardial electrograms, to changes in dispersion of depolarization and repolarization during localized ventricular ischemia.
Methods And Results:
Ventricular epicardial electrograms were recorded from 5 anesthetized pigs with a 127-electrode sock. A controllable suture snare was used to ligate the left anterior descending coronary artery (LAD). The chest was reclosed, and a vest with 256 ECG electrodes was fitted to the torso. Simultaneous arrays of epicardial electrograms and torso ECGs were recorded during LAD occlusion and reperfusion. Activation-recovery intervals (ARIs), QTu and RTu dispersion (where u indicates upstroke), and QRST integrals were calculated, and these data were fitted to anatomically customized computational models of the swine ventricular epicardium and torso. LAD occlusion caused the epicardial ARI dispersion to steadily increase, whereas the location of shortest ARI shifted from the posterobasal ventricular tissue (control) to the anteroapical myocardium, distal to the suture snare. These changes were associated with a steady increase in the torso RTu dispersion as the shortest RTu interval moved from the right shoulder (control) to the sternum. QTu and RTu dispersion determined from the 12-lead ECG did not consistently reflect the myocardial changes.
Conclusions:
Although changes in myocardial repolarization dispersion resulting from localized ischemia are not reliably reflected in temporal indices derived from the 12-lead ECG, they can be readily identified with high-resolution torso ECG mapping.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...