A new approach to determining the content and 15N abundance of total dissolved nitrogen in aqueous samples: TOC
1UFZ Centre for Environmental Research Leipzig-Halle, Germany. russow@bdfl.ufz.de
Abstract:
The standard method for determining the 15N abundance of total dissolved nitrogen (TDN) in aqueous samples (e.g., soil leachate, sewage, urine) is currently Kjeldahl digestion followed by steam distillation or diffusion to isolate the ammonium, and then 15N measurement using IRMS. However, this technique is both time-consuming and laborious. One way of overcoming these disadvantages could be to couple a TOC analyser to determine the TDN with a sufficient quadrupole MS to determine the 15N abundance. The high TOC analyser (Elementar Analysensysteme Hanau, Germany), which catalytically oxidises the sample's total nitrogen with a high, constant yield to nitrogen monoxide (NO), appeared particularly suitable. The quadrupole-MS ESD 100 (InProcess Instruments Bremen, Germany) proved to be a suitable mass spectrometer for the 15N determination of NO. This combination of instruments was found to provide a workable method in numerous measurements of standard and actual samples. The detection limit concerning the N amount required per analysis is 2 microg, corresponding to an N concentration of 0.7 mg/l in a maximum sample volume of 3ml. Depending on the N concentration, 15N abundances starting from 0.5 at.% can be measured with the required precision of better than 3% (simple standard deviation). For example, measuring the abundance of 0.5 at.% requires about 50 microg N, whereas for 1 at.% or more only about 5 microg N is needed per analysis.
More Related Videos
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
2D NMR: Overview of Heteronuclear Correlation Techniques
Tandem Mass Spectrometry
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Other Nuclides: 31P, 19F, 15N NMR
While fluorine-19 and phosphorous-31 have high natural abundances (100%) and positive gyromagnetic ratios, nitrogen-15 has a low natural abundance and a negative gyromagnetic ratio. However, nitrogen-15 is still preferred over nitrogen-14 (which has a high...
The Equilibrium Constant