Related Experiment Video
Updated: Aug 9, 2026

Inactivation of Pathogens via Visible-Light Photolysis of Riboflavin-5′-Phosphate
Published on: April 6, 2022
Endotoxin inactivation in water by using medium-pressure UV lamps
W B Anderson1, P M Huck, D G Dixon
1Department of Civil Engineering. Department of Biology, University of Waterloo, Waterloo, Ontario, Canada N2L 3G1. wbanderson@uwaterloo.ca
Abstract:
Deionized water was spiked with various concentrations of endotoxin and exposed to UV irradiation from medium-pressure UV lamps to assess endotoxin inactivation. It was found that endotoxin inactivation was proportional to the UV dose under the conditions examined. The inactivation rate was determined to be approximately 0.55 endotoxin unit/ml per mJ/cm(2) of irradiation delivered.
More Related Videos
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Temperature
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Chemical Agents for Microbial Control
Microbial Wastewater Treatment