Laboratory Estimation of Net Trophic Transfer Efficiencies of PCB Congeners to Lake Trout (Salvelinus namaycush) from Its Prey
Published on: August 29, 2014
Trace analysis of trichlorobenzenes in fish by microwave-assisted extraction and gas chromatography-electron-capture
Gyula Wittmann1, Tom Huybrechts, Herman Van Langenhove
1Department of Inorganic and Analytical Chemistry, Faculty of Science, University of Szeged, P.O. Box 440, Szeged H-6701, Hungary. wittmann@chem.u-szeged.hu
Abstract:
An analytical method consisting of extraction, clean-up, and analysis by gas chromatography-electron-capture detection (GC-ECD) was developed for the determination of trichlorobenzenes (TCBs) in fish samples. Two extraction methods, saponification and liquid-liquid extraction (S-LLE), and microwave-assisted extraction (MAE), were evaluated. In both cases, n-pentane was used as the extraction solvent. For S-LLE, the recoveries ranged from 66.6+/-9.1% for 1-bromo-4-chlorobenzene (4-BCB) to 93.5+/-4.9% for 1,2,4-trichlorobenzene (1,2,4-TCB). The recoveries were significantly lower, between 31.0+/-3.9% for 1,2,3-trichlorobenzene (1,2,3-TCB) and 52.3+/-3.0% for 1,3,5-trichlorobenzene (1,3,5-TCB), in the absence of fish. Proteins and glycerides of the fish tissue seemed to compete with TCBs for the base, and hence decreased their decomposition rate. In the case of MAE, the recoveries were highly dependent on the pressure applied during extraction. At 5 bar, much higher recoveries were obtained, from 66.7+/-15.6% for 4-BCB to 79.9+/-13.6% for 1,2,4-TCB, than at 1 bar. Sulfur formation was, however, observed at 5 bar, and interfered with the GC-ECD analysis of TCBs. Sulfur was adequately removed by copper powder treatment, which was shown not to affect the recovery of analytes. The recoveries of target analytes by S-LLE and MAE did not differ statistically (t-test, alpha = 0.01). Both methods were appropriate for the detection of TCBs at concentration levels typically observed in marine biota, i.e. approximately 1 ng/g. S-LLE was, however, more time consuming, and required larger volumes of high-purity organic solvents than MAE.
More Related Videos
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...