Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
Biofeedback of R-wave-to-pulse interval normalizes blood pressure
Harald Rau1, Michael Bührer, Rolf Weitkunat
1Department of Psychiatry, Hospital Gilead, Bethel, Remterweg 69/71, D 33617 Bielefeld, Germany. hrau@psychiatrie.gilead.de
Abstract:
We investigated whether biofeedback of the R-wave-to-pulse interval, a measure related to the pulse wave velocity, enables participants with either high or low arterial blood pressure to modify their blood pressure. Twelve participants with high blood pressure (mean systolic blood pressure = 142.6 +/- 13.5 mmHg; mean diastolic blood pressure = 99.9 +/- 12.3 mmHg) and 10 participants with low blood pressure (mean systolic blood pressure = 104.8 +/- 6.6 mmHg; mean diastolic blood pressure = 73.2 +/- 4.2 mmHg) received 3 individual sessions of RPI biofeedback within a 2-week period. Participants with high blood pressure were rewarded for decreasing and participants with low blood pressure for increasing their blood pressure. Standard arm-cuff blood pressure measurements across the sessions served as dependent variables. Participants with high blood pressure achieved significant reductions of systolic (15.3 mmHg) and diastolic (17.8 mmHg) blood pressure levels from the beginning of the first to the end of the last training session. In contrast, participants with low blood pressure achieved significant increases in systolic (12.3 mmHg) and diastolic (8.4 mmHg) blood pressure levels. The degree of blood pressure changes in this study might be of clinical relevance. With prolonged and refined training regimens, even larger effects seem to be likely.
More Related Videos
09:56Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
14:28Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...