Large-volume programmed-temperature vaporiser injection for fast gas chromatography with electron capture and mass
P Tollbäck1, J Björklund, C Ostman
1Department of Analytical Chemistry, Stockholm University, 106 91 Stockholm, Sweden.
Abstract:
A large volume injection fast-GC-MS method has been developed, optimized and evaluated for the determination of polybrominated diphenyl ethers, including the decabrominated diphenyl ether (BDE-209). The programmed-temperature vaporiser injection parameters, temperature programming of the GC oven, and the physical dimensions of the narrow bore GC column were investigated to find the optimal operating conditions for the analysis. Depending on parameter settings the yield of the PBDEs and particularly BDE-209, varies significantly. Volumes up to 125 microl were successfully injected and a fast GC separation was performed, with retention times as short as 6.4 min for the last eluting compound, BDE-209. In a pilot study an air sample, collected at an electronics dismantling facility, was analyzed. Low-resolution mass spectrometry in electron capture negative ion mode was used for detection. Nine BDE congeners, including BDE-209, were identified and quantified.
More Related Videos
05:22Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II