Mammography with computer-aided detection: reproducibility assessment initial experience.

Bin Zheng1, Lara A Hardesty, William R Poller

  • 1Department of Radiology, University of Pittsburgh and Magee-Womens Hospital, Imaging Research, Suite 4200, 300 Halket St, Pittsburgh, PA 15213, USA. zhengb@msx.upmc.edu

Radiology
|May 22, 2003
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Regulatory crosstalk between KLF5, miR-29a and Fbw7/CDC4 cooperatively promotes atherosclerotic development.

Biochimica et biophysica acta. Molecular basis of disease·2017
Same author

Near-Infrared Light Triggered Upconversion Optogenetic Nanosystem for Cancer Therapy.

ACS nano·2017
Same author

Non-contact method to freely control the radiation patterns of antenna with multi-folded transformation optics.

Scientific reports·2017
Same author

Cost Effectiveness of Imatinib, Dasatinib, and Nilotinib as First-Line Treatment for Chronic-Phase Chronic Myeloid Leukemia in China.

Clinical drug investigation·2017
Same author

Improving Performance of Breast Cancer Risk Prediction by Incorporating Optical Density Image Feature Analysis: An Assessment.

Academic radiology·2017
Same author

Preliminary study on ultrasound-guided prostate biopsy specimen scores.

Experimental and therapeutic medicine·2017

This study evaluated a computer-aided detection (CAD) system for mammography, finding improved reproducibility in marking microcalcifications and masses. However, consistent identification of true-positive masses requires further enhancement for clinical application.

Area of Science:

  • Radiology and Medical Imaging
  • Artificial Intelligence in Healthcare
  • Biomedical Engineering

Background:

  • Computer-aided detection (CAD) systems aim to improve mammography interpretation accuracy.
  • Evaluating the performance and reproducibility of CAD systems is crucial for clinical adoption.
  • Previous CAD systems have shown variable results in detecting mammographic abnormalities.

Purpose of the Study:

  • To assess the performance and reproducibility of a commercial computer-aided detection (CAD) system.
  • To analyze the CAD system's ability to detect microcalcifications and masses on mammograms.
  • To evaluate the consistency of CAD system markings across multiple analyses.

Main Methods:

  • One hundred mammographic examinations with biopsy-confirmed positive findings were analyzed.

Related Experiment Videos

  • The CAD system performed three repeated analyses on each of the four-view mammograms.
  • Detection sensitivity for abnormalities and specific regions was compared across the three analyses.
  • Main Results:

    • The CAD system achieved high reproducibility for microcalcification clusters (96.0% marked on all three images).
    • Abnormality-based sensitivity for mass detection ranged from 66.7% to 70.8%.
    • Reproducibility of true-positive mass region markings was 69.5%, while false-positive mass region markings were less reproducible (44.0%).

    Conclusions:

    • The CAD system demonstrates improved reproducibility, particularly due to reduced false-positive rates.
    • Consistent identification of true-positive masses by the CAD system remains a significant challenge.
    • Further development is needed to enhance the reliability of mass detection for clinical practice.