Related Experiment Videos
Development and validation of analytical methods for monomeric and oligomeric migrants from nylon 12 packaging
N H Stoffers1, F Brandl, J P H Linssen
1Fraunhofer Institute for Process Engineering and Packaging, Giggenhauser Strasse 35, 85354 Freising, Germany. stoffers@ivv.fraunhofer.de
Abstract:
Analytical methods for the determination of laurolactam--the monomer of nylon 12--as well as the cyclic dimer and trimer were established. High performance liquid chromatography using ultraviolet (HPLC-UV) and mass spectrometric detection (HPLC-MS) were both found suitable to identify and quantify monomer, cyclic dimer and trimer well below the specific migration limit (SML) of laurolactam, being 5 mg/kg of food (simulant). Gas chromatography with flame ionisation detection (GC-FID) showed to be an appropriate method for the detection of only laurolactam in aqueous and fatty food simulants. Food simulants could be analysed directly by all three methods, or after a change of solvents. For olive oil, a method for sample clean-up by size-exclusion chromatography (SEC) was established.