Related Experiment Video
Updated: Sep 25, 2026

Laboratory Estimation of Net Trophic Transfer Efficiencies of PCB Congeners to Lake Trout (Salvelinus namaycush) from Its Prey
Published on: August 29, 2014
Determination of polychlorinated biphenyls in serum using gas chromatography-mass spectrometry with negative chemical
1Finnish Institute of Occupational Health, Topeliuksenkatu 41 a A, FIN-00250 Helsinki, Finland. helena.kontsas@ttl.fi
Abstract:
A sensitive and selective method for the determination of 24 polychlorinated biphenyls (PCBs) by gas chromatography-mass spectrometry with negative chemical ionization (GC-MS-NCI) was applied for the recent needs of occupational exposure in waste incineration. The three most abundant ions were used in determining compounds with at least five chlorine atoms in the PCB molecule. Selecting ions Cl(35) and Cl(37) for di-, tri-, and tetrachlorinated PCBs resulted in reliable quantification of these compounds. The detection limits for the 24 individual compounds varied from 0.01 to 0.08 microg/l. The recovery of the method was 113+/-16%. Stability tests showed no degradation of the compounds studied during 6 weeks. The sum of 24 PCB compounds measured from the sera of workers in a disposal plant was 1.9-10.9 microg/l, and 0.3-3.0 microg/l for controls, respectively. The mean proportion of the low chlorinated PCB compounds (with four or less chlorine atoms) was 20% for workers in the disposal plant and 14% for the controls.
More Related Videos
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
05:20Determination of 45 Pesticides in Avocado Varieties by the QuEChERS Method and Gas Chromatography-Tandem Mass Spectrometry
Published on: December 8, 2023
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Chemical Ionization (CI) Mass Spectrometry