Atmospheric pressure chemical ionization-mass spectrometry method to improve the determination of dansylated
François Gaboriau1, René Havouis, Jacques-Philippe Moulinoux
1Groupe de Recherche en Thérapeutique Anticancéreuse, Faculté de Médecine, 2 Av. du Pr. Léon Bernard, F-35043 Rennes Cedex, France. francois.gaboriau@univ-rennes1.fr
Abstract:
Determination of polyamine pools is still a step impossible to circumvent in studies aimed at determining the pathophysiological role of natural polyamines. In addition, polyamine measurement in biological fluids and tissues may have clinical relevance, especially in cancer patients. Among the wide panel of analytical methods developed for the quantification of polyamines, high-performance liquid chromatographic (HPLC) separation of polyamines after derivatization with dansyl chloride remains the most commonly used method. In this work, we show that atmospheric pressure chemical ionization-mass spectrometry (MS) can be used to detect and quantify biologically relevant polyamines after dansylation, without chromatographic separation. Positive-ion mass spectra for each dansylated polyamine were generated after optimization by flow injection analysis (FIA). FIA coupled with MS detection by selected ion monitoring greatly increased the sensitivity of the polyamine detection. The method is linear over a wide range of polyamine concentrations and allows detection of quantities as low as 5 fmol. The FIA/MS method is about 50-fold more sensitive than the conventional HPLC/fluorimetry procedure. A good correlation (r>0.98) between these two methods was observed. The FIA/MS method notably reduces the time of analysis per sample to 1.5 min and turns out to be rapid, efficient, cost saving, reproducible, and sufficiently simple to allow its routine application.
More Related Videos
08:10Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry
Published on: July 14, 2017
12:49Quantification of Site-specific Protein Lysine Acetylation and Succinylation Stoichiometry Using Data-independent Acquisition Mass Spectrometry
Published on: April 4, 2018
Related Concept Videos
Chemical Ionization (CI) Mass Spectrometry
Mass Spectrometry of Amines
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
High-Performance Liquid Chromatography: Types of Detectors
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Spectrometry: Amine Fragmentation
In amines, the number of nitrogen atoms affects the mass of the molecular ion, which is described by the nitrogen rule of mass spectrometry. This rule states that a compound containing a single or...