Related Experiment Video
Updated: Jul 15, 2026

Conducting Elevated Temperature Normal and Combined Pressure-Shear Plate Impact Experiments Via a Breech-end Sabot Heater System
Published on: August 7, 2018
Primary electronic thermometry using the shot noise of a tunnel junction
Lafe Spietz1, K W Lehnert, I Siddiqi
1Department of Applied Physics, Department of Physics, Yale University, New Haven, CT 06520, USA. lafe.spietz@yale.edu
Abstract:
We present a thermometer based on the electrical noise from a tunnel junction. In this thermometer, temperature is related to the voltage across the junction by a relative noise measurement with only the use of the electron charge, Boltzmann's constant, and assumption that electrons in a metal obey Fermi-Dirac statistics. We demonstrate proof-of-concept operation of this primary thermometer over four orders of magnitude in temperature, with as high as 0.1% accuracy and 0.02% precision in the range near 1 kelvin. The self-calibrating nature of this sensor allows for a much faster and simpler measurement than traditional Johnson noise thermometry, making it potentially attractive for metrology and for general use in cryogenic systems.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case, then the...
Electronic Distance Measuring Instruments

