Related Experiment Video
Updated: Aug 4, 2026

09:44
Pretargeted Radioimmunotherapy Based on the Inverse Electron Demand Diels-Alder Reaction
Published on: January 29, 2019
Effect of increased (99m)Tc/(99)Tc ratios on count rates in sentinel node procedures: a randomised study
G M M Gommans1, F M van der Zant, T G van der Schors
1Department of Nuclear Medicine, Westfries Gasthuis Hoorn, 1620 AR Hoorn, The Netherlands. g.m.m.gommans@wfg.nl
Summary
A 2-hour elution of technetium-99m-colloid albumin (99mTc-Nanocoll) significantly increases sentinel lymph node (SLN) count rates in breast cancer patients. This method is reliable, whether performed simultaneously with lumpectomy or after prior excision biopsy.
Area of Science:
- Nuclear medicine
- Oncology
- Surgical oncology
Background:
- Sentinel lymph node (SLN) biopsy is crucial for breast cancer staging.
- Optimizing radiotracer preparation can enhance SLN detection rates.
- Technetium-99m (99mTc)-based radiocolloids are commonly used for SLN procedures.
Purpose of the Study:
- To evaluate the impact of different technetium-99m to technetium-99 ratios in (99m)Tc-Nanocoll on sentinel lymph node (SLN) count rates.
- To compare the efficacy of SLN procedures performed simultaneously with lumpectomy versus those performed after prior excision biopsy.
Main Methods:
- A double-blinded randomized study involving 161 breast cancer patients.
- Preparation of (99m)Tc-colloid albumin with varying elution times (2-hour vs. 24-hour).
- Ex vivo gamma probe measurements of excised SLNs to determine count rates (counts per second).
Main Results:
- A 2-hour elution yielded significantly higher SLN count rates compared to a 24-hour elution (P<0.004).
- No significant difference in SLN count rates was observed when comparing simultaneous procedures with those performed after prior excision biopsy within the same elution groups.
- SLN procedures demonstrated reliability regardless of timing relative to lumpectomy or prior excision biopsy.
Conclusions:
- A 2-hour elution of (99m)Tc-Nanocoll in vacuum maximizes specific activity, leading to higher SLN count rates.
- The timing of SLN procedures (simultaneous vs. delayed) does not significantly impact reliability.
- (99m)Tc-Nanocoll prepared with a 2-hour elution is an effective radiotracer for sentinel lymph node identification in breast cancer.