Simultaneous determination of vitamin K analogs in human serum by sensitive and selective high-performance liquid
Hiroyuki Wakabayashi1, Kenji Onodera, Susumu Yamato
1Department of Clinical Pharmacotherapy, Faculty of Pharmaceutical Sciences, Niigata University of Pharmacy and Applied Life Sciences, Niigata, Japan. waka@niigata-pharm.ac.jp
Objectives:
We report a sensitive and selective method for the simultaneous determination of vitamin K1 and K2 analogs (VKs) with high-performance liquid chromatography in which a platinum catalyst reduction column and an electrochemical detector operated in the oxidation mode are incorporated into the detection system. We also applied this trace analysis method to the simultaneous determination of VKs in human serum to investigate the physiologic and pathophysiologic roles of VKs in the bone metabolism.
Methods:
Our high-performance liquid chromatographic method with postcolumn catalyst reduction and electrochemical detection was applied for the simultaneous determination of VKs in human serum samples. After separation of VKs on a reversed-phase separation column by using a mixture of ethanol and methanol (1:1, v/v), containing 0.025 M of sodium perchlorate as the mobile phase, the VKs were reduced once in a platinum catalyst reduction column connected online and then monitored quantitatively by an electrochemical detector with a glassy carbon working electrode operated in the oxidation mode (+0.6 V versus Ag/AgCl).
Results:
VKs were clearly separated from each other within 80 min. The detection limits at a signal-to-noise ratio of 3 were 2 to 10 pg for VKs. Quantitative recovery from serum was obtained in the range of 86% to 91% for VKs. The average coefficients of variation of within-day and between-day assays were 1.6% to 2.1% and 2.4% to 3.6%, respectively, for all VKs.
Conclusions:
This method was sensitive and selective for detection of VKs and was satisfactory in the simultaneous determination of VKs in small volumes of human serum.
More Related Videos
07:32Detection of 3-Nitrotyrosine in Atmospheric Environments via a High-performance Liquid Chromatography-electrochemical Detector System
Published on: January 30, 2019
07:34Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Vitamins