Related Experiment Video
Updated: Jul 13, 2026

The WATCHMAN Left Atrial Appendage Closure Device for Atrial Fibrillation
Published on: February 28, 2012
An evaluation of the modified Airway Management Device
R Sivasankar1, U B Bahlmann, M R Stacey
1Department of Anaesthetics, University Hospital of Wales, Cardiff CF14 4XW, UK. rs_sankar123@hotmail.com
Abstract:
We evaluated the modified Airway Management Device (AMDTM) in 60 spontaneously breathing anaesthetised patients. The insertion and removal of the device was very easy and atraumatic. The airway was secured on the first attempt in 41 patients (70%; 95% CI 57-80%). The most important problem was loss of airway, which occurred in 11 patients (19%; 11-30%) during maintenance of anaesthesia. The AMD was dislodged during maintenance in one patient. There was a loss of the airway in 12 patients (20%; 12-31%); in 10, it was maintained with simple airway manoeuvres or a laryngeal mask airway and tracheal intubation was required in two patients. Ten of these patients were male and two were female; the failure rate was 33% (12-31%) among the male patients and 6% (2-22%) among the female patients. The cuff volumes ranged from 4 ml to 80 ml and cuff pressures from 6 cm H2O to 92 cm H2O. Blood was seen on removal in three patients (6%; 2-16%) and nine patients (18%; 10-30%) experienced sore throat after removal of the device.
Related Concept Videos
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques