Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Beat-to-beat noninvasive stroke volume from arterial pressure and Doppler ultrasound
Johannes J van Lieshout1, Karin Toska, Erik Jan van Lieshout
1Room F7-205, Academic Medical Center, Department of Internal Medicine and Cardiovascular Research Institute Amsterdam, University of Amsterdam, PO Box 22700, 1100 DE Amsterdam, The Netherlands. j.j.vanlieshout@amc.uva.nl
Abstract:
The proper understanding of the cardiovascular mechanisms involved in complaints of short-lasting dizziness and the evaluation of unexplained recurrent syncope requires continuous monitoring of cardiac stroke volume (SV) in addition to blood pressure and heart rate. The primary aim of the present study was to evaluate a pulse wave analysis method that calculates beat-to-beat flow from non-invasive arterial pressure by simulating a non-linear, time-varying model of human aortic input impedance (Modelflow; MF), by comparing MF stroke volume (SV(MF)) to Doppler ultrasound (US) flow velocity SV (SV(US)). A second purpose was to compare the two methods under two different conditions: the supine and head-up tilt (30 degrees ) position. SV(US) and SV(MF) with non-invasive arterial pressure (Finapres) as input to the aortic model were measured beat-to-beat during spontaneous supine breathing and in the passive 30 degrees head-up tilt (HUT30) position in six normotensive healthy humans [three females, mean age 24 (21-26) years]. There were variations in supine SV track between the two methods with zero difference and a SD of the beat-to-beat difference (MF-US) of 4.2%. HUT30 induced a systematic difference of 10.5% and an increase in SD to 6.9%, which was reproducible. Beat-to-beat changes in SV in the supine resting condition were equally well assessed by both methods. Systematic differences appear during HUT30 and show opposite signs. The difference between the two methods upon a change in body position may be attributed to limitations in each method.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...