Related Experiment Videos
Improving the transient response of a bolt-clamped Langevin transducer using a parallel resistor
1Department of Electrical Engineering, National United University, 1 Lien-Kung Road, Kungjing Li, 36012, ROC, Miaoli, Taiwan. ktchang@mail.nlhu.edu.tw
Abstract:
This paper suggests a parallel resistor to reduce DC time constant and DC response time of the transient response, induced immediately after an AC voltage connected to a bolt-clamped Langevin transducer (BLT) is switched off. An equivalent circuit is first expressed. Then, an open-circuit transient response at the terminals induced by initial states is derived and measured, and thus parameters for losses of the BLT device are estimated by DC and AC time constants of the transient response. Moreover, a driving and measuring system is designed to determine transient response and steady-state responses of the BLT device, and a parallel resistor is connected to the BLT device to reduce the DC time constant. Experimental results indicate that the DC time constant greatly exceeds the AC time constant without the parallel resistor, and greatly decreases from 42 to 1 ms by a 100-kOmega parallel resistor.