Practical approaches to fast gas chromatography-mass spectrometry
Katerina Mastovská1, Steven J Lehotay
1USDA, Agricultural Research Service, Eastern Regional Research Center, 600 East Mermaid Lane, Wyndmoor, PA 19038, USA.
Abstract:
Fast gas chromatography-mass spectrometry (GC-MS) has the potential to be a powerful tool in routine analytical laboratories by increasing sample throughput and improving laboratory efficiency. However, this potential has rarely been met in practice because other laboratory operations and sample preparation typically limit sample throughput, not the GC-MS analysis. The intent of this article is to critically review current approaches to fast analysis using GC-MS and to discuss practical considerations in addressing their advantages and disadvantages to meet particular application needs. The practical ways to speed the analytical process in GC and MS individually and in combination are presented, and the trade-offs and compromises in terms of sensitivity and/or selectivity are discussed. Also, the five main current approaches to fast GC-MS are described, which involve the use of: (1) short, microbore capillary GC columns; (2) fast temperature programming; (3) low-pressure GC-MS; (4) supersonic molecular beam for MS at high GC carrier gas flow; and (5) pressure-tunable GC-GC. Aspects of the different fast GC-MS approaches can be combined in some cases, and different mass analyzers may be used depending on the analytical needs. Thus, the capabilities and costs of quadrupole, ion trap, time-of-flight, and magnetic sector instruments are discussed with emphasis placed on speed. Furthermore, applications of fast GC-MS that appear in the literature are compiled and reviewed. At this time, the future usefulness of fast GC-MS depends to some extent upon improvement of existing approaches and commercialization of interesting new techniques, but moreover, a greater emphasis is needed to streamline overall laboratory operations and sample preparation procedures if fast GC-MS is to become implemented in routine applications.
More Related Videos
09:09Semi-Quantitative Analysis of Peptidoglycan by Liquid Chromatography Mass Spectrometry and Bioinformatics
Published on: October 13, 2020
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Applications of the Ideal Gas Law: Molar Mass, Density, and Volume