Severe immune haemolysis in a group A recipient of a group O red blood cell unit
M L Barjas-Castro1, M F Locatelli, M A Carvalho
1Haematology and Transfusion Centre, State University of Campinas, Campinas, Sao Paulo, Brazil. maluz@unicamp.br
Haemolysis caused by passive ABO antibodies is a rare transfusional complication. We report a case of severe haemolytic reaction in a 38-year-old man (blood group A) with lymphoma who had received one red blood cell (RBC) unit group O. After transfusion of 270 mL, the patient experienced fever, dyspnoea, chills and back pain. On the following morning he was icteric and pale. Haptoglobin was inferior to 5.8 mgdL(-1), haemoglobin was not increased and lactate dehydrogenase was elevated. Haemolysis was evident on observation of the patient's post-transfusion samples. The recipient's red cells developed a positive direct antiglobulin test and Lui elution showed anti-A coated the cells. Fresh donor serum had an anti-A titre of 1024, which was not reduced by treating the serum with dithiothreitol. Donor isoagglutinin screening has been determined by microplate automated analyser and showed titre higher than 100. Physicians should be aware of the risk of haemolysis associated with ABO-passive antibodies. There is generally no agreement justifying the isoagglutinin investigation prior to transfusion. However, automated quantitative isoagglutinin determination could be part of the modern donor testing process, mainly in blood banks where identical ABO group units (platelets or phenotyped RBCs) are not available owing to limited supply.
Haemolysis caused by passive ABO antibodies is a rare transfusional complication. We report a case of severe haemolytic reaction in a 38-year-old man (blood group A) with lymphoma who had received one red blood cell (RBC) unit group O. After transfusion of 270 mL, the patient experienced fever, dyspnoea, chills and back pain. On the following morning he was icteric and pale. Haptoglobin was inferior to 5.8 mgdL(-1), haemoglobin was not increased and lactate dehydrogenase was elevated. Haemolysis was evident on observation of the patient's post-transfusion samples. The recipient's red cells developed a positive direct antiglobulin test and Lui elution showed anti-A coated the cells. Fresh donor serum had an anti-A titre of 1024, which was not reduced by treating the serum with dithiothreitol. Donor isoagglutinin screening has been determined by microplate automated analyser and showed titre higher than 100. Physicians should be aware of the risk of haemolysis associated with ABO-passive antibodies. There is generally no agreement justifying the isoagglutinin investigation prior to transfusion. However, automated quantitative isoagglutinin determination could be part of the modern donor testing process, mainly in blood banks where identical ABO group units (platelets or phenotyped RBCs) are not available owing to limited supply.
More Related Videos
06:29Methods for Quantitative Detection of Antibody-induced Complement Activation on Red Blood Cells
Published on: January 29, 2014
11:59Detection of Residual Donor Erythroid Progenitor Cells after Hematopoietic Stem Cell Transplantation for Patients with Hemoglobinopathies
Published on: September 6, 2017
Related Concept Videos
Blood Transfusion and Agglutination
History
The history of blood transfusion dates back to the 17th century, when early attempts were made in animals. In 1818 James Blundell, a British doctor, performed the first successful human blood transfusion. Later in 1900, Karl...
Blood Transfusion
Blood Transfusion Overview
A blood transfusion is a medical procedure used to replace blood lost due to injury, surgery, or to treat conditions such as anemia or cancer. During a transfusion, donor blood is...
Rh Blood Group
The ABO Blood Group
Antigens in the ABO Blood Group System
Antigens are substances that can trigger an immune response, leading to the production of antibodies. In the ABO blood group system,...
Blood Typing
Antigens are protein molecules that reside on the surface of red blood cells (RBCs). The ABO and Rh blood typing systems target antigens A,...
Hypersensitivity Reactions: Cytolytic Reactions