Related Experiment Video
Updated: Sep 20, 2026

Quantification of the Immunosuppressant Tacrolimus on Dried Blood Spots Using LC-MS/MS
Published on: November 8, 2015
Determination of ticlopidine in human plasma by capillary gas chromatography with ion trap detection
Angelina Pena1, Celeste Lino, M Irene N Silveira
1Laboratory of Bromatology, Faculty of Pharmacy, University of Coimbra, 3000 Coimbra, Portugal. apena@ci.uc.pt
Abstract:
A gas chromatographic method for determination of ticlopidine in human plasma using mass spectrometric detection was developed. A Perkin Elmer model 8500 gas chromatograph coupled to an ion trap detector (ITD) in electron impact mode (EI) was used. The gas chromatograph was fitted with a 30 m x 0.32 mm i.d., DB-17 capillary column with a film thickness of 0.25 microm. The compounds were isolated from plasma by Extrelut-1 solid-phase extraction using hexane as the solvent of elution. The detection and quantification limits for this method were 0.005 and 0.01 microg/ml, respectively. The calibration curves were linear from 0.01 and 2.5 microg/ml. Recoveries from human plasma spiked at 0.01 and 2.0 microg/ml ranged from 84.4 and 87.3%. The coefficient of variation (CV) was between 5.1 and 6.9%. The results show that the sensitivity, accuracy and precision of the method are adequate for the determination of ticlopidine in human plasma samples. The ITD in SIM mode allows the unequivocal identification of ticlopidine. The suitability of this method was evaluated in the determination of ticlopidine in plasma from healthy volunteers following oral administration of a dose of 500 mg/day.
More Related Videos
06:08Evaluation of Drug Sorption to PVC- and Non-PVC-based Tubes in Administration Sets Using a Pump
Published on: March 11, 2017
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Thin-Layer Chromatography (TLC): Overview
To begin the analysis, a mixture of compounds is spotted on the starting line on the TLC plate using a thin capillary. The bottom of the...