Related Experiment Video
Updated: Sep 20, 2026

Collection and Extraction of Occupational Air Samples for Analysis of Fungal DNA
Published on: May 2, 2018
Indoor health: background levels of fungi
Ronald E Gots1, Nancy J Layton, Suellen W Pirages
1International Center for Toxicology and Medicine, 2301 Research Blvd., Suite 210, Rockville, MD 20850, USA.
Abstract:
There is no uniformity in the suggested guidelines for acceptable levels of fungi in indoor ambient air. Thus, health professionals have no way to determine what levels of fungi may pose a threat to human health. The authors reviewed the published literature to identify data reported for noncomplaint structures, that is, structures in which occupants did not have health concerns associated with the quality of the indoor air. For both commercial and residential structures, fungal concentrations detected were often higher than currently suggested guidance values. The average indoor air concentration in 149 noncomplaint commercial buildings was 233 colony forming units (CFU) per cubic meter, whereas outdoor ambient air levels averaged 983 CFU/m(3). Total indoor spore counts ranged from 610 to 1040 spores/m(3) in three commercial buildings. Outdoor total spore counts associated with these buildings ranged from 400 to 80,000 spores/m(3). The average indoor concentration reported for 820 noncomplaint residential structures was 1252 CFU/m(3) with an average outdoor level of 1524 CFU/m(3). Total spore counts detected indoors at 85 residential structures ranged from 68 to 2307 spores/m(3). Outdoor spore levels associated with these structures ranged from 400 to 80,000 spores/m(3). A large proportion of both commercial and residential noncomplaint structures have indoor ambient air fungal concentrations above 500 CFU/m(3), a level often advocated as requiring remediation in structures when occupants complain of nonspecific adverse health symptoms.
Insights
Indoor air quality guidelines for fungi lack uniformity, leaving health professionals uncertain about safe levels. Studies show many non-complaint buildings exceed suggested fungal concentration limits.
Area of Science:
- Environmental Health
- Mycology
- Indoor Air Quality
Background:
- Current guidelines for acceptable indoor fungi levels are inconsistent, hindering health professionals' ability to assess risks.
- Occupants in non-complaint structures, experiencing no health issues, often have indoor fungal concentrations exceeding suggested limits.
Purpose of the Study:
- To review published literature on fungal concentrations in indoor ambient air of non-complaint commercial and residential structures.
- To compare indoor fungal levels in healthy environments with existing, non-uniform guidance values.
Main Methods:
- Literature review of published studies reporting fungal data from indoor ambient air.
- Analysis of data from commercial and residential structures where occupants reported no health concerns.
Main Results:
- Average indoor fungal concentration in 149 non-complaint commercial buildings was 233 colony forming units (CFU)/m³, compared to 983 CFU/m³ outdoors.
- Average indoor fungal concentration in 820 non-complaint residential structures was 1252 CFU/m³, compared to 1524 CFU/m³ outdoors.
- A significant percentage of both commercial and residential non-complaint structures exceeded 500 CFU/m³, a common threshold for remediation.
Conclusions:
- Existing fungal concentration data in non-complaint indoor environments often surpasses current suggested guidelines.
- The lack of standardized guidelines for indoor fungi poses challenges for health professionals in determining potential health threats.