X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
[Evaluation of patient entrance dose rate of interventional X-ray equipment]
Shigeru Miyazaki1, Shinji Abe, Yoh Katoh
1Department of Radiology, Ohashi Hospital, Toho University.
Abstract:
Because interventional radiology (IVR) procedures are being performed with increasing frequency, patient X-ray exposure dose for X-ray fluoroscopic and radiographic procedures should not be ignored. In order to avoid excessive X-ray exposure, exposure dose rate limits are specified in the Japanese Industrial Standards (JIS) and by civil law at 50 mGy/min for usual fluoroscopy and 125 mGy/min for high-dose fluoroscopy. In the present study, we examined the difference in patient incident dose rate before and after using an X-ray generator that satisfied the above requirements. For incident dose to the image intensifier (I.I.), we investigated the differences between continuous and pulsed fluoroscopy, the effects of additional filters (Ta: tantalum, Al: aluminum), and the form of the X-ray spectrum. For pulsed fluoroscopy using PMMA (polymethyl-methacrylate), the maximum patient incident dose rates of usual and high-dose fluoroscopy were 59 mGy/min and 151 mGy/min, respectively. With regard to I.I. incident dose, saturation was observed beginning at a PMMA of 20 cm, and the X-ray dose was insufficient. In terms of the difference in patient incident dose rate with Ta and Al filters, the dose rate with the Ta filter was approximately 50% lower than that with the Al filter except for the saturation area. Concerning the X-ray spectrum, it was considered that a Ta filter not only minimizes patient X-ray exposure (because Ta reduces soft X-rays more effectively than Al) but also minimizes scattered X-rays because it filters out hard X-rays, leading to improved image quality. However, the use of the filter is appropriate only when a sufficient I.I. incident dose can be ensured. Specifically, the use of the filter under saturation conditions can lead to deterioration in image quality. Therefore, IVR X-ray systems must be equipped with an appropriate filter for reducing X-ray exposure while maintaining a sufficient I.I. incident dose rate.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
X-ray Imaging
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies III: Computed Tomography