Related Experiment Video
Updated: Aug 12, 2026

Intra-cardiac Side-Firing Light Catheter for Monitoring Cellular Metabolism using Transmural Absorbance Spectroscopy of Perfused Mammalian Hearts
Published on: May 12, 2019
Development of catheter-type optical oxygen sensor and applications to bioinstrumentation
Kosuke Tsukada1, Shuhei Sakai, Kentaro Hase
1Department of Applied Physics and Physico-Informatics, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku, Yokohama, Kanagawa 223-8522, Japan. ktsukada@med.kawasaki-m.ac.jp
Abstract:
A catheter-type optical oxygen sensor based on phosphorescence lifetime was developed for medical and animal experimental use. Since the sensor probe should have biocompatibility and high oxygen permeability in vivo, we focused attention on acceptable polymer materials for contact lenses as the substrates of probes. Pd-porphyrin was doped in silicone-based polymer, and was fixed at the edge of an optical fiber inserted in a catheter tube. The shape of the probe was 600 microm in diameter and 100 microm in thickness, and the probe had high oxygen permeability of Dk value 455. In accuracy evaluation, there found an excellent correlation between the pO2 values measured through phosphorescence lifetime using the oxygen sensors and those measured as the calibrating data using oxygen electrodes. The response time required to achieve 90% from reversible default value to be from 150 to 0 mmHg, and from 0 to 150 mmHg was 15.43 and 7.52 s, respectively. In addition, other properties such as temperature and pH dependency, response, and durability of our optical oxygen sensor were investigated. In animal experiments, the catheter-type oxygen sensor was inserted via the femoral artery of a rat, and arterial oxygen pressure was monitored under asphyxiation. The sensor was valid in the range of oxygen concentration sufficient for biometry, and expected to be integrated with an indwelling needle.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
08:13Evaluations of Oxygenation and Vascular Perfusion in Pre-Clinical Models of Cancer and Wound Healing Using OS-DCE OAI
Published on: April 7, 2026
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Amperometry: Overview
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Microbial Biosensors