Related Experiment Video
Updated: Sep 20, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Capillary electrochromatography of methylated benzo[a]pyrene isomers. II. Effect of stationary phase tuning
1Center of Biotechnology and Drug Design, Department of Chemistry, Georgia State University, 38 Peach Tree Center Avenue, Atlanta, GA 30303, USA.
Abstract:
For Part II of our ongoing study, we present a strategy for stationary phase optimization for the capillary electrochromatographic (CEC) separation of the 12 methylated benzo[a]pyrene (MBAP) isomers. Utilizing the optimum mobile phase conditions from Part I of our study as a guide, seven commercially available stationary phases have been evaluated for their ability to separate highly hydrophobic MBAP isomers. Ranging in design from high-performance liquid chromatography (HPLC) to CEC application, each phase was slurry packed in house and tested for CEC suitability and performance. Several stationary phase parameters were investigated for their effects on MBAP separation including bonding type (monomeric or polymeric, % carbon loading, surface coverage), pore size, particle size, and type of alkyl substituent. In this manner, the present state of commercially available packings has been assessed in our laboratory. Utilizing the optimum polymeric C18-5 microm-100 A-PAH stationary phase, the effects of CEC packed bed length and capillary inside diameter (I.D.) were also evaluated. A 50 microm I.D. capillary, 25 cm packed bed length and 75% (v/v) acetonitrile, 12.5 mM Tris, pH 8.0, 20 degrees C at 30 kV, provided resolution of 11 out of 12 MBAP isomers thus showing the effectiveness of CEC for analysis of structurally similar methylated polyaromatic hydrocarbons.
Related Concept Videos
NMR Spectroscopy of Benzene Derivatives
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Ion-Exchange Chromatography
Electrophoresis: Overview
There...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...

