Related Experiment Video
Updated: Apr 9, 2026

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
INR self-management permits lower anticoagulation levels after mechanical heart valve replacement
H Koertke1, K Minami, D Boethig
1Heart and Diabetes Center North Rhine-Westphalia Bad Oeynhausen, Germany, Clinic of the Ruhr University of Bochum, Bochum, Germany. hkoertke@hdz-nrw.de
Background:
The Early Self Controlled Anticoagulation Trial (ESCAT I) showed that anticoagulation self-management after mechanical heart valve replacement decreased complication rates by maintaining INR levels closer to the target range than International Normalized Ratio (INR) home doctor management. The therapeutic range for the INR in that study was between 2.5 and 4.5 for all positions of prosthetic valves. ESCAT II should find out whether lowering the target range for INR self-management would further reduce complication rates.
Methods:
ESCAT II is a prospective controlled randomized (valves: St. Jude Medical Standard or Medtronic Hall, treatment: conventional/low-dose) multicenter study with 3,300 patients. We present interim results of 1,818 patients. 908 were categorized as having a low-dose target range, which was INR 1.8 to 2.8 for prostheses in aortic position and 2.5 to 3.5 for prostheses in mitral position or in combined valve replacement. The control group (conventional group) with 910 patients aimed at an INR of 2.5 to 4.5 for all valve positions.
Results:
In the conventional group, 74% of INR values measured were within the therapeutic range. In the low-dose group, 72% of the values were within that range. The linearized thromboembolism rate (% per patient year) was 0.21% for both groups. The bleeding complication rate was 0.56% in the low-dose regimen group versus 0.91% in the conventional group.
Conclusions:
Early onset INR self-management under oral anticoagulation after mechanical heart valve replacement enables patients to keep within a lower and smaller INR target range. The reduced anticoagulation level resulted in fewer grade III bleeding complications without increasing thromboembolic event rates.