Three methods for improving oxygen delivery efficiency--transtracheal oxygen therapy (TTO), reservoir cannula, and demand-pulse oxygen delivery--are currently available. We discuss our experiences of TTO and its characteristics compared with the other two methods. Since 1988, we have tried to apply TTO to the candidates for home oxygen therapy (HOT) fulfilling the following criteria: 1) good activity and enthusiasm to daily life, 2) high oxygen flow rate with nasal cannula, 3) complicating nasal disorders such as chronic sinusitis, or 4) suffering complications from nasal cannula therapy. We used a disposable 8-Fr feeding tube for a trnastracheal catheter. Patients were taught to change their catheters themselves every day by simply removing the old and reinserting the new catheter. We have experienced nine patients on HOT with TTO. A half to a third of the flow rate of nasal cannular was required with TTO to achieve an equivalent PaO2 level. In cases with hypercapnea, a persistent significant increase of PaCO2 was not found. We measured arterial blood gases, changing the distance from the tract opening to the catheter tip, and it was suggested that in each case there may be an optimum distance to achieve the highest PaO2 level. Seven cases received TTO for more than 18 months, a mean of 30.2 months (range 19.3-48.9) and HOT for a mean of 26.6 months. They all maintained a high degree of enthusiasm for TTO. Two cases could return to work. Five cases enjoyed active daily lives, such as shopping, going out for recreation, travelling, and attending concerts.(ABSTRACT TRUNCATED AT 250 WORDS)
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:15Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
Related Concept Videos
Oxygen Transport in the Blood
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes: