Randomised trial of cardiotocography alone or with ST waveform analysis for intrapartum monitoring
J Westgate1, M Harris, J S Curnow
1Department of Obstetrics and Biomedical Engineering, Plymouth General Hospital, Freedom Fields, UK.
It is possible to record the fetal electrocardiographic waveform (ECG) from the scalp electrode used in labour for detection of fetal heart rate. Animal and observational studies of changes in the ST waveform of the ECG during hypoxia suggest that a combination of heart rate and ST waveform analysis might improve the predictive value of intrapartum monitoring. In a randomised trial, we have studied intervention rates and neonatal outcome for high-risk labours monitored either by conventional cardiotocography (CTG) or by ST waveform analysis plus CTG. 1200 women with pregnancy of at least 34 weeks' gestation were assigned to the groups when the decision to apply a fetal scalp electrode was made. Neonatal outcome was assessed by umbilical-cord blood gas analysis, Apgar scores, resuscitation needed, and postnatal course. All recordings were retrospectively viewed by an observer unaware of clinical details to check adherence to the trial protocol. The addition of ST waveform monitoring to CTG substantially reduced the proportion of deliveries for fetal distress (ST + CTG 27/615 vs CTG 58/606; p less than 0.001). The groups did not differ in rate of operative delivery for other reasons, incidence of asphyxia at birth, or neonatal outcome. Metabolic acidosis and low 5 min Apgar scores were less common in the ST + CTG than the CTG group, but not significantly so. The only case of birth asphyxia in the ST + CTG group was identified by both heart rate and ST changes. The review of recordings showed that the reduction in intervention rate was among cases with CTG patterns classified as normal or intermediate, whereas there was no difference in intervention rates among cases with abnormal recordings. Our findings confirm that ST waveform analysis discriminates CTG changes in labour and that our protocol for interpretation is safe. Further randomised studies are warranted.
It is possible to record the fetal electrocardiographic waveform (ECG) from the scalp electrode used in labour for detection of fetal heart rate. Animal and observational studies of changes in the ST waveform of the ECG during hypoxia suggest that a combination of heart rate and ST waveform analysis might improve the predictive value of intrapartum monitoring. In a randomised trial, we have studied intervention rates and neonatal outcome for high-risk labours monitored either by conventional cardiotocography (CTG) or by ST waveform analysis plus CTG. 1200 women with pregnancy of at least 34 weeks' gestation were assigned to the groups when the decision to apply a fetal scalp electrode was made. Neonatal outcome was assessed by umbilical-cord blood gas analysis, Apgar scores, resuscitation needed, and postnatal course. All recordings were retrospectively viewed by an observer unaware of clinical details to check adherence to the trial protocol. The addition of ST waveform monitoring to CTG substantially reduced the proportion of deliveries for fetal distress (ST + CTG 27/615 vs CTG 58/606; p less than 0.001). The groups did not differ in rate of operative delivery for other reasons, incidence of asphyxia at birth, or neonatal outcome. Metabolic acidosis and low 5 min Apgar scores were less common in the ST + CTG than the CTG group, but not significantly so. The only case of birth asphyxia in the ST + CTG group was identified by both heart rate and ST changes. The review of recordings showed that the reduction in intervention rate was among cases with CTG patterns classified as normal or intermediate, whereas there was no difference in intervention rates among cases with abnormal recordings. Our findings confirm that ST waveform analysis discriminates CTG changes in labour and that our protocol for interpretation is safe. Further randomised studies are warranted.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Mitral Stenosis II: Clinical features and Diagnostic Tests
Acute Coronary Syndrome III: Diagnostic Studies
Dysrhythmias V: Evaluating Dysrhythmias
