Analysis of the motion of 2-dimensional patterns: evidence for a second-order process
Related Experiment Video
Updated: Oct 17, 2026

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
A M Derrington1, D R Badcock, S A Holroyd
1Department of Physiological Sciences, Medical School, Newcastle upon Tyne, England.
Abstract:
The sum of two differently orientated moving sinusoidal gratings of similar spatial frequency, contrast, and velocity appears as a single coherent "plaid" pattern. The visual system is thought to analyse the motion of plaids in two stages, first analysing the motion of the (1-D) components, and then calculating a speed and direction which is consistent with those 1-D motions. We studied the apparent direction of motion of plaids made by adding two components that had the same spatial frequency and contrast, and were symmetrically oriented about the vertical axis. The gratings moved in jumps, and we studied the effect of varying the size of the jump, the angle between the component gratings, and the temporal interval between the jumps, on the perceived direction of motion. When the size of the jumps was increased to 3/8 of their spatial period, the perceived direction of motion of the plaid pattern reversed, although if one component were presented alone, its direction of movement did not reverse. Reversed motion of this type was consistently obtained if the angle between the components was greater than about 140 degrees, if the interval between jumps was at least 25 msec, and if the spatial frequency of the component gratings was less than about 4 c/deg. When the angle between the components was smaller, or the time between jumps was greater, most observers saw normal motion in the direction predicted by the two-stage hypothesis. When the spatial frequency was raised, observers saw no consistent motion.(ABSTRACT TRUNCATED AT 250 WORDS)
More Related Videos
11:00Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
11:03An Analog Macroscopic Technique for Studying Molecular Hydrodynamic Processes in Dense Gases and Liquids
Published on: December 4, 2017
Related Concept Videos
Interference and Diffraction
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Simple Harmonic Motion and Uniform Circular Motion
There is an easy way to produce simple harmonic motion by using uniform circular motion. For instance, consider a ball attached to a uniformly rotating...
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the drone...
Relative Motion Analysis - Acceleration
Partial Differential Equations