Related Experiment Video
Updated: Aug 31, 2026

Using a Combination of Indirect Calorimetry, Infrared Thermography, and Blood Glucose Levels to Measure Brown Adipose Tissue Thermogenesis in Humans
Published on: June 2, 2023
Comparison of digital infrared thermal imaging (DITI) with contact thermometry: pilot data from a sleep research
Cameron J van den Heuvel1, Sally A Ferguson, Drew Dawson
1The Centre for Sleep Research, University of South Australia, Level 5 Basil Hetzel Institute, The Queen Elizabeth Hospital, Woodville, SA 5011, Australia. cameron.vdh@unisa.edu.au
Abstract:
Body temperature regulation is associated with changes in sleep propensity; therefore, sleep research often necessitates concomitant assessment of core and skin surface temperatures. Attachment to thermistors may limit the range of movement and comfort, introducing a potential confound that may prolong sleep initiation or increase wakefulness after sleep onset. It has been suggested that contact thermometry may artificially increase temperatures due to insulation. We report here on a method of remote sensing skin temperatures using a digital infrared thermal imaging (DITI) system, which can reduce these potential confounds. Using data from four healthy young adult volunteers (age = 26.8 +/- 2.2 years; mean +/- SEM), we compared measures of skin temperature using a DITI system with contact thermometry methods already in use in our sleep laboratory. A total of 416 skin temperature measurements (T(sk)) were collected from various sites, resulting in an overall correlation coefficient of R = 0.99 (p < 0.0001) between both methods. Regression analyses for individuals resulted in correlation coefficients between 0.80 and 0.97. These pilot results suggest that DITI can assess skin surface temperatures as accurately as contact thermometry, provided the interest is in relative and not absolute temperature changes. This and some other important limitations are discussed in more detail hereafter.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...