Related Experiment Video
Updated: Aug 30, 2026

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Determination of Myocardial Viability with ECG-Gated Fluorodeoxyglucose F-18 Positron Emission Tomography
Hee Seung Bom1, John P. Vansant, Roderic I. Pettigrew
1Emory Center for Positron Emission Tomography, Atlanta, GA, USA
Abstract:
OBJECTIVE: We hypothesize that ECG-gated positron emission tomography (PET) using Fluorodeoxyglucose F-18 (FDG) alone can determine myocardial viability by identifying dysfunctional myocardium with preserved glucose metabolism. We compared the contraction-metabolism pattern of gated FDG PET with the perfusion-metabolism pattern of conventional PET using N-13 ammonia (NH(3)) as a perfusion agent and FDG as a glucose metabolism agent in 21 consecutive patients with chronic coronary artery disease with left ventricular dysfunction (mean ejection fraction 23.6 +/- 7.7%).METHODS: The left ventricle was divided into 17 segments. Uptakes of NH(3) and FDG were scored from absent (0) to normal (4), and wall motion was scored from dyskinesia (-1) to normal (3). Scores were determined by the visual interpretation of the majority of 3 blinded expert readers. Viable myocardium was defined by normal or mildly reduced uptakes of both NH(3) and FDG, perfusion-metabolism mismatch on NH(3)-FDG PET, or normal to mildly reduced uptake of FDG with regional dysfunction on gated FDG PET.RESULTS: Gated FDG PET identified 184 segments as viable, all of which were determined as viable by NH(3)-FDG PET. Among 125 segments identified as nonviable by NH(3)-FDG PET, 76 segments were determined as nonviable by NH(3)-FDG PET. The results provided a positive and negative predictive value of gated FDG PET for the determination of myocardial viability to be 100% and 60.8%, respectively.CONCLUSIONS: Gated FDG PET has a high positive predictive value (100%) for the identification of viable myocardium.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Acute Coronary Syndrome III: Diagnostic Studies
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...